Ordering Info.

Napco Commercial Fire Kits

GEMC-FW-255KT

255 Point GEM-C Firewolf™ 24V Commercial Fire System Kit

  • 24V Panel, 255 Points via commercial addressable, wireless or conventional fire devices, 4 on board NACs providing up to 6.5A notification power
  • 7 Amp, 24V Power Supply
  • Built in horn/strobe sync. module on each NAC
  • Built in dual line communicator; dual onboard serial ports
  • SLC Loop Card included.
  • Quickloader up/downloading including remote smoke obscuration reporting
  • Locking, Large Red Enclosure, 16 x 25” reversible door, with 14.25” x 25” base. Houses up to 32Ah battery backup.
  • Menu-driven LCD Fire Annunciator mounts anywhere on bus. (Also, full keyswitch support)

GEMC-FW-128KT

128 Point GEM-C Firewolf™ 24V Commercial Fire System Kit

As above, but with

  • 24V Panel, 128 Points via commercial addressable, wireless or conventional fire devices, 4 on board NACs providing up to 6.5A notification power. SLC Loop Card included. (Second SLC Loop Card is optional.)

GEMC-FW-32KT

32 Point GEM-C Firewolf™ 24V Commercial Fire System Kit

Similar to above, but with

  • 24V Panel, 32 Points via commercial addressable, wireless or conventional fire devices, 2 on board NACs providing up to 4A notification power.
    SLC Loop Card included. (Second SLC Loop Card is optional.)
  • Locking, Medium Red Enclosure, 16 x 17” door, with 14.25” x 16” base. Houses up to 16Ah battery backup.

GEMC-FW32CONVKT

32 Point GEM-C Conventional Commercial Fire System Kit, ideal for sprinkler/waterflow apps. 24V Panel, 32 Points via commercial addressable, wireless or conventional fire devices, 4 on board NACs providing up to 6.5A notification power

  • Locking, Medium Red Enclosure, 16 x 17” door, with 14.25” x 16” base. Houses up to 16Ah battery backup.
  • 4 Amp, 24V Power Supply
  • Conventional 8-zone 2-wire fire input module, for conventional 2-wire smokes or any conventional fire detection device (GEMC-F8ZCPIM)
  • Built in horn/strobe sync. module on each NAC
  • Built in dual line communicator; dual onboard serial ports
  • Quickloader up/downloading including remote smoke obscuration reporting (for addressable detectors)
  • Menu-driven LCD Fire Annunciator mounts anywhere on bus (GEMC-FK1)

Conventional Fire System Peripherals

GEMC-FK1

LCD Fire Red Annunciator (Menu-driven operation, functionality for Reset, Acknowledge, Silence (with disable).

GEMC-F8ZCPIM

Conventional 8-zone 2-wire fire input module. Plugs into motherboard, for conventional 2-wire smoke detectors or any conventional fire detection device.

GEMC-EZM8

8-point Expansion Module

FWC-CNV-PULL

Conventional Single Action Pull Station, with Hex Reset

FWC-CNV-PULLK

Conventional Single Action Pull Station, with Key Reset

FWC-CNV-PULL2

Conventional Dual Action Pull Station, with Hex Reset

FWC-CNV-PULL2K

Conventional Dual Action Pull Station, with Key Reset

Wireless Firewolf Peripherals

GEMC-WL-SMK

Gemini Commercial Wireless Smoke, Photoelectric (complete).

GEMC-WL-HEAT

Gemini Commercial Wireless Heat, 135º F

GEMC-WL-WD2

Gemini Comml Wireless Input Module converts any UL listed device into a UL wireless device (ex., pull stations or sprinkler supervisories.)

GEMC-REVC

Gemini Commercial Wireless 255 point RF Receiver (up to 4 per system, max.)

GEMC-WL-CO

Wireless Carbon Monoxide Detector

Addressable Firewolf Peripherals

GEMC-FW-SLC

Addressable SLC Fire Module, supports up to 128 addressable SLC fire devices, below. Up to 2 connect to Panel.

FWC-FSLC-SMK

Addressable Analog SLC Smoke, photoelectric, head**

FWC-FSLC-HEAT

Addressable Analog SLC Heat, 135 - 150ºF, head**

FWC-FSLC-DUCT

Addressable SLC Duct smoke detector, photoelectric (Requires use of GEMC-24VR Voltage Regulator) Inclds 2 onboard relays that follow state of detector.

FWC-FSLC-DUCTRA

Remote Indicator Plate with LED indicator & key reset.

FWC-FSLC-EZM2

Addressable SLC 2-zone conventional expansion module. Uses one address on SLC loop, but yields 2 indep. contact monitoring circuits, for pull stations, water flow and other dry contact alarm initiating devices.

FWC-FSLC-EZM1

Addressable SLC 1-input conventional module, similar to usage above.

FWC-FSLC-CZM

Addressable SLC Conventional Zone module, for montoring of dry contacts, ie., pull stations and conv. smokes (Requires use of GEMC-24VR Voltage
Regulator) Creates a 24V 2-wire fire zone on the SLC loop, selectable Class A or B zone wiring.

FWC-FSLC-RM2

Addressable SLC 2-output module (requires 2 SLC addresses)

FWC-FSLC-ISO

Addressable SLC Short Circuit Module (Optional: For special applications, meets Class A, Style 7 loop reqts.)

FWC-FSLC-SOM1

Addressable SLC Fire supervised output module. Application examples: elevator recall, HVAC shutdown, add’l NAC output w/ power supply
(Requires use of GEMC-24VR Voltage Regulator)

FWC-FSLC-PULL

Addressable SLC Fire Pull Station, standard hex-key reset.

FWC-FSLC-PULLK

Addressable SLC Fire Pull Station, with key reset.

FWC-FSLC-PULL2

Dual action, pull station with hex-key reset.

FWC-FSLC-PULL2K

Dual action pull station, with key reset.

FWC-FSLC-PROG2

Tool for address-programming SLC devices

FWC-FSLC-SMK6B

** Smoke/Heat 6" Base, required for FWC-FSLC- SMK and –HEAT devices

Output Options

GEMC-NAC7S

Remote 4-output NAC Extender, for 6.5A ttl, or 2A, max. on any 1 output. Red 14 x 16” can, connects to 120VAC, supports 24V 16Ah standby batts.
Supervised, fire bus connection. System Sensor and Wheelock NAC sync. (5/system, for 20 add’l NAC circuits ttl.). 3 Programmable relay outputs;
2 low voltage; 1 high-voltage 120V rated relay.

GEMC-12V2APS-CF

12VDC Power Supply for Fire Bus, remote supervised. Direct 120VAC connection, supports 2ea. 12V, 7Ah to 16Ah standby batts.

GEMC- FPRINT

Parallel Printer Module

GEMC-RM3008

8 Form C Relay Output Module

GEMC-RS232

RS232 Adapter for serial output from Panel

GEMC-OUT8

PGM Output Module, 8 open collector PGM outputs

Communication Options

GEMC-NL-MOD

Internet Reporting Module

SLE-CDMA-FIRE

StarLink Universal Sole Path Fire Cellular Communicator, CDMA Network, works with virtually any 12-24V FACP, virtually anywhere in US. Verizon Network Certified. Meets or exceeds UL864 9th Ed., 1610, 985,1023,1635 & NFPA 72 2013, 2010, 2007 code.

SLE-GSM-FIRE

StarLink Universal Sole Path Fire Cellular Communicator GSM Network, as above, but communicates on GSM 3/4G Cellular Network.

find a distributor find a Napco salesman Napco international company media info investors library employment

 

333 Bayview Avenue, Amityville, NY 11701 (631) 842-9400 Fax: (631) 789-9292 email: salesinfo@napcosecurity.com
Copyright 2011, Napco Security Technologies, Inc. All rights reserved